Non-bituminous materials

A2.8.3
The compacted thickness of all individual lifts of non-bituminous materials must be in accordance with Table A2.6.
Table A2.6 Compacted lift thickness – Non-bituminous materials
Material Compacted lift thickness (mm)
Minimum at any point Nominal lift thickness Maximum at any point
CBGM base 100 120 to 150 200

C25/30 concrete

100 As required As existing

C32/40 concrete

100 As required As existing
GSB1 75

100 to 150

200

Classes A & B

75

100 to 150

200

Classes C & D

75

100 to 150

200

SMF-A & SMF-B

75

100 to 150

200

SMF-C & SMF-D 75

100 to 150