Skip to main content
HAUC
HAUC

Base preparation

S6.8.1
All surfaces must be free of contamination before applying the bond coat. This is especially important after the removal of any sand separation layer.
S6.8.2
A bond coat must be applied to the surface of all bound layers before overlaying in all circumstances.
S6.8.3
The bond coat must be applied at a rate that ensures a minimum residual bitumen content of 0.15 kg/m2 .
S6.8.4
Multiple lifts of the same material laid during a single visit on the same day do not require treatment between lifts. However, a bond coat must be applied before placing the permanent surface course for work carried out in accordance with S6.5.
S6.8.5
A bitumen emulsion edge sealant may be used as a bond coat in small openings and narrow trenches.