To ensure you get the best experience, this website uses cookies.
- S10.3.8
- Vibrotampers are permitted for compacting reinstatement materials in accordance with the following requirements:
- S10.3.9
-
50 kg minimum nominal mass
- The width of the foot must not exceed 5 mm/kg of the nominal mass.
- The contact length of the foot must not exceed 350 mm nor be less than 175 mm.
- The foot contact area must not exceed 1000 mm2/kg of the nominal mass.
- The mass of any extension leg must not exceed 10% of the nominal mass.
- S10.3.10
-
25 to 50 kg nominal mass – permitted in restricted areas only
- The width of the foot must not exceed 150 mm.
- The contact length of the foot must not exceed 200 mm.